DEFIBRILLATOR Waveform: Rectilinear Biphasic • Defibrillator Charge Hold Time: 30 seconds • Energy Selection: Automatic preprogrammed selection (120J, 150J, 200J) • Patient Safety: All patient connections are electrically isolated. • Charge Time: Less than 10 seconds with new batteries. • Electrodes: ZOLL CPR-D padz or stat padz II . • Built in Defibrillator Self Test: Included • CPR: Metronome Rate: Variable 60 to 100 CPM • Depth: 1/2" to 3"; 1.3 to 7.8 cm. • Defibrillation Advisory: Evaluates electrode connection and patient ECG to determine if defibrillation is required. Shockable Rhythms: Ventricular fibrillation with average amplitude >100 microvolts and wide complex ventricular tachycardia with rates greater than 150 BPM. For ECG Analysis Algorithm Accuracy for sensitivity and specificity performance, refer to AED Plus Administrator’s Guide. • Patient Impedance Measurement Range: 0 to 300 ohms • Defibrillator: Protected ECG Circuitry • Display Format: Optional LCD with Moving Bar • Size: 2.6" x 1.3"; 6.6 cm x 3.3 cm • Viewing Time: 2.6 seconds • Display Sweep Speed: 25 mm/sec; 1"/sec • Battery Capacity: Typical new (20°C) = 5 years (300 shocks) or 1.5 hours continuous Monitoring/Defibrillation. End of life designated by Red X (typical remaining shocks = 100, 0.5 hours continuous Monitoring/Defibrillation). • PC Minimum Requirements for configuration and patient data recovery: Windows® 98, Windows® 2000, Windows®NT, Windows® XP, IBM-compatible PII with 16550 UART (or higher) computer. 64MB RAM. VGA monitor or better. CD-ROM drive. IrDA port. 2MB disk space.
DEVICE Size: (H x W x D) 5.25"x 9.50" x 11.50"; 13.3 cm x 24.l cm x 29.2 cm • Weight: 6.7 lbs.; 3.1 kg • Power: User Replaceable Batteries. 10 -Type 123A Photo Flash lithium manganese dioxide batteries. • Device Classification: Class II and internally powered per EN60601-1 • Design Standards: Meets applicable requirements of UL 2601, AAMI DF-39, IEC 601-2-4, EN60601-1, IEC60601-1-2.
ENVIRONMENT Operating Temperature: PS Model: 32. to 122.F; 0. to 50.C; PA Model: 50. to 104.F; 10. to 40.C • Storage Temperature: PS Model: -22. to 158.F; -30. to 70.C; PA Model: 32. to 122.F; 0. to 50.C • Humidity: 10 to 95% relative humidity, non-condensing • Vibration: MIL Std. 810F, Min. Helicopter Test • Shock: PS Model: IEC 68-2-27; 100G; PA Model: IEC 68-2-27; 50G • Altitude: PS Model: -300 to 15,000 ft.; -91m to 4573m; PA Model: -300 to 7,500 ft.; -91m to 2287m • Particle and Water Ingres IP-55.
CPR-D padz Shelf Life: 4 years • Conductive Gel: Polymer Hydrogel • Conductive Element: Tin • Packaging: Multilayer foil laminate pouch • Impedance Class: Low • Cable Length: 36 in (91 cm) • Sternum: Length: 6.1 in (15.5 cm); Width: 5.0 in (12.7 cm); Length, conductive gel: 3.5 in (8.9 cm); Width, conductive gel: 3.5 in (8.9 cm); Area, conductive gel: 12.3 sq in (79.0 sq cm) • Apex: Length: 6.1 in (15.5 cm); Width: 5.6 in (14.1 cm); Length, conductive gel: 3.5 in (8.9 cm); Width, conductive gel: 3.5 in (8.9 cm); Area, conductive gel: 12.3 sq in (79.0 sq cm) • Complete assembly: Folded Length: 7.6 in (19.4 cm); Folded width: 7.0 in (17.8 cm); Folded height: 1.5 in (3.8 cm) • Design standards: Meets applicable requirements of ANSI/AAMI/ISO DF-39-1993.